TEMPERATURE CONTROL 4 TUTORIAL


INTRODUCTION

In this tutorial, you will add an indicator that displays the number of iterations the loop has performed, add a wait function to slow the loop iterations down, replace the Temperature control with a random number function and replace the Thermometer indicator with a waveform graph.

  • Open the Tutorial 3.vi and Save as 4.vi
  • Add a Numeric Digital Indicator to Show Loop Iterations
  • Add a Wait MS Function to the Loop
  • Replace the Temperature Control with a Random Number Function
  • Replace the Thermometer Indicator with a Waveform Chart
  • Run the VI and Observe the Results
  • Save the VI and Exit Labview

OPEN TUTRIAL 3.VI AND SAVE AS

Open tutorial_3.vi and Save As to tutorial_4.vi


ADD A NUMERIC DIGITAL INDICATOR TO SHOW LOOP ITERATIONS

Add a Numeric Digital Indicator to the Front Panel and rename its label to Iterations

Place it above the On/Off switch

Wire it to the Iteration Terminal on the Block Diagram

Your Control Panel and Block Diagram should look like this:


RUN THE VI AND OBSERVE THE RESULTS

Flip on the On/Off switch and run the VI

You should observe the iterations in the Iterations indicator on the Front Panel

Notice that the iterations are counting up very fast

Stop the VI with the On/Off Switch


ADD A WAIT MS FUNCTION TO LOOP

Add a Functions > Time and Dialogue > Wait (ms) function to the Block Diagram

Place it to the right of the Greater? function

Add a Functions > Numeric > Numeric Constant to the Block Diagram and enter 500 in it

Wire the Numeric Constant to the left (input) side of the Wait (ms) function

Your Block Diagram should look like this:


RUN THE VI AND OBSERVE THE RESULTS

Toggle On/Off switch to On and run the VI

The Iteration indicator should be counting every half second

Toggle the On/Off switch to Off


REPLACE THE TEMPERATURE CONTROL WITH A RANDOM NUMBER FUNCTION

Delete the Temperature control from the Front Panel

This should remove its terminal from the Block Diagram

Delete any bad wires

Add a Functions > Numeric > Multiply function to the Block Diagram; place it where the Temperature control terminal was

Add a Functions > Numeric > Random Number (0-1) to the Block Diagram; place it to the upper-left of the Random Number (0-1) function

Add a Functions > Numeric > Numeric Constant to the Block Diagram and enter 100 in the Numeric Constant's terminal; place it to the lower-left of the Random Number (0-1) function

Wire the added functions together

Your Front Panel and Block Diagram should look something like this:


RUN THE VI AND OBSERVE THE RESULTS

Change the Threshold indicator to 50 (if it isn't already)

Toggle On/Off switch to On and run the VI

You should see the Thermometer indicator varying temperatures between 0 and 100 degrees every half second

Toggle the On/Off switch to Off


REPLACE THERMOMETER INDICATOR WITH A WAVEFORM GRAPH

Select (with window select) the Threshold control and Overtemp indicator and move them to the left

Select (with window select) the On/Off switch and Iteration indicator and move them to the right

Note: This is just to make more room for the Waveform Graph

Delete the Thermometer indicator from the Front Panel and delete any bad wires from the Block Diagram

The Thermometer indicator's terminal should also be deleted from the Block Diagram

Add a Control > Graph > Waveform Chart to the Front Panel

Modify the Waveform Chart's Y axis to range from 0 to 100

Wire the Waveform Chart's terminal to the output of the Multiply function on the Block Diagram

Your Front Panel and Block Diagram should look like this:


RUN THE VI AND OBSERVE THE RESULTS

Change the Threshold indicator to 50 (if it isn't already)

Toggle On/Off switch to On and run the VI

You should see the Waveform Chart indicator plotting a temperature between 0 and 100 degrees every half second

The Overtemp indicator should be indicating an Overtemp about half the time

Toggle the On/Off switch to Off




SAVE THE VI AND EXIT LABVIEW