Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
electronmicroscopy:start [2012/01/27 13:56] – chris | electronmicroscopy:start [2020/03/06 09:04] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== OSU Microscopy Center ====== | ====== OSU Microscopy Center ====== | ||
- | [[http:// | + | [[http:// |
+ | |||
+ | Tate group contact is Bethany Matthews < | ||
* FEI NOVA NanoSEM 230 - High resolution SEM with in lens detector | * FEI NOVA NanoSEM 230 - High resolution SEM with in lens detector | ||
* FEI Quanta 3D SEM/ | * FEI Quanta 3D SEM/ | ||
- | * FEI Quant 600F FE SEM | + | * FEI Quanta |
* Philips CM12 STEM | * Philips CM12 STEM | ||
* Leica DM 5000 Optical Microscope | * Leica DM 5000 Optical Microscope | ||
* Sample Preparations | * Sample Preparations | ||
* Simulation Software | * Simulation Software | ||
+ | |||
+ | ===== Guides ===== | ||
+ | {{: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ===== Tutorials ===== | ||
+ | * [[http:// | ||
+ | * [[https:// | ||
+ | |||
+ | ===== Titan Update 22 Nov 2013 from Pete Eschbach ===== | ||
+ | |||
+ | Recently we have had both spectacular nano particle images come from the Titan and other images that are not so high quality. | ||
+ | |||
+ | Nano Particle Grid Preparation | ||
+ | Pete Eschbach and Teresa Sawyer | ||
+ | Electron Microscope Facility, OSU | ||
+ | |||
+ | 1. First step is to select the grid for the job. We have a handout in the lab in the grey inboxes on the South side of conference room. Please ask us if you have questions, we are here to help. An ounce of preparation saves a pound of grief later! | ||
+ | |||
+ | A new alternative is Quantafoil from EMS, EMS numbers such as Q225-CR2. | ||
+ | 2. Plasma treat your grids to make them hydrophilic (attract water). | ||
+ | 3. Now get 3 tweezers with O ring to lock the jaws of the tweezer. | ||
+ | 4. Now dispense 2-3 uL of your nanoparticle suspension on the grid. | ||
+ | 5. Wick off excess after 1 -2 minutes. | ||
+ | 6. Let it dry overnight in a clean dry nitrogen cabinet or a desiccated cabinet. | ||
+ | 7. Release your grid into a grid box by moving the O Ring off the tweezer. | ||
+ | 8. Lab staff will be happy to show the fine points for grid preparation. | ||
+ | |||
+ | |||
+ | |||
+ | ===== Update 1 Feb 201? from Yi Liu ===== | ||
+ | Dear Colleagues, | ||
+ | |||
+ | More updates in EM Facility below: | ||
+ | |||
+ | Nova NanoSEM 230 high-resolution SEM has been installed and signed-off, and will be ready for use from the beginning of next week. Functions are summarized below: | ||
+ | |||
+ | - 1 nm Resolution at 15 kV, less than 1.6 nm at 1 kV; | ||
+ | - High vacuum mode (conductive sample) and low vacuum mode (non-conductive samples); | ||
+ | - X-Ray EDS chemical analysis (EDAX, Inc); | ||
+ | - | ||
+ | - | ||
+ | - Through-Lens Detector (TLD) inside the column (immersion mode), for detection of SE and BSE signals, suitable for working distance < 5mm and high resolution imaging; | ||
+ | - Low vacuum high contrast detector (vCD) for low kV image, especially when electron decelerating function is used; | ||
+ | | ||
+ | | ||
+ | In order to make training smoothly, we will start training to users who have already authorized to use either Quanta 3D, or Quant 600F. | ||
+ | |||
+ | The installation of Titan 80-200 high resolution TEM will be started next week or the following week. | ||
+ | Philips CM12 STEM will be decommissioned by the end of February, no later than end of March, depending the progress of the installation of new TEM. | ||
+ | |||
+ | More are coming! | ||
+ | |||
+ | Best Regards, | ||
+ | Yi | ||
+ | |||
+ | Yi Liu, Ph.D, Director | ||
+ | Electron Microscopy Facility | ||
+ | 145 Linus Pauling Science Center | ||
+ | 2900 SW Campus Way | ||
+ | Oregon State University | ||
+ | Corvallis, OR 97331 | ||
+ |