80, 120 waveforms from TDS1012B 100 ns/div --> 244 periods per waveform freq = 244.39 MHz vs 244.370 on the scope. fwhm < 10 kHz 25 mVpp same jfet oscillator as used for the 240 MHz data, just Vdd and Vgs have been tweaked. Also, metal cover improves stability.