Physical
Characteristics |
Size Enclosure
|
75” (Length) X 35”
(Width) X 55” (Height) Fully enclosed, suitable for outdoor
installation
|
Ratings/Performance |
Output*
|
7 kW continuous 10
kW for 30 minutes 15 kW for 0.5 seconds
|
Voltage |
120/240 VAC @ 60 Hz
100/230 VAC @ 50 Hz
|
Systems
Performance Simple Cycle
Efficiency |
Natural
Gas |
36% @ 2 kW
output 29% @ 7 kW output |
LP
Gas |
34% @ 2 kW
output 27% @ 7 kW output
|
Cogen
Efficiency Operating
Temperature Exhaust Temperature
|
> 75% 160°
F 220° F
|
Power
Quality
|
IEEE 519 or
better
|
Emissions |
NOx < 1ppm SOx
< 1ppm
|
Operating Conditions |
Temperature |
-20° F to 104° F
(standard) -40° F to 120° F (with optional upgrades)
|
Elevation |
Up to 6,000 feet
(standard) > 6,000 feet (with optional upgrade)
|
Operating
Characteristics |
Fuel |
Type |
Natural Gas LP
Gas
|
Supply Pressure |
> 1/4 PSIG
|
Maintenance Intervals |
Routine |
8,000
hours |
Major Components |
40,000 operating
hours
|
Design
Life |
15 years
|
Noise |
< 65 dBa @ 1 meter
|
* Rated at 1.0 power factor, 77° F, 500
feet
elevation |